ALUMINUM, URINE

Order Flexilab
ALU-U   ALUUQ
 
Synonyms Al, Urine
SPECIMEN REQUIREMENTS
Container Type 24-hour dark plastic urine container.
Specimen Type 24-hour urine collection or random urine collection.
Preferred Volume 10 mL
Minimum Volume 5 mL
Collection Procedure Collect a 24-hour urine in a 24-hour dark plastic urine container or a random urine collection. Refrigerate during collection.
Specimen Processing Aliquot 10 mL of a well-mixed 24-hour urine collection or random urine collection into a leakproof plastic urine container. Store and transport refrigerated. ARUP studies indicate that refrigeration of urine alone, during & after collectio preserves specimens adequately if tested within 14 days of collection. Record total volume and collection time. Submit specimen in two ARUP Trace Element-Free Transport Tubes (43116).
Required Patient Info Collection period, volume.
Stability Room Temp 1 week   Refrigerated 2 weeks   Frozen (-20°C) 1 year  
Unacceptable Conditions Urine collected within 48 hours after administration of gadalinium (Gd) containing contrast media (may occur with MRI studies) or acid preserved urine specimens.
Reference Laboratory ARUP
Reference Lab Test Code 99408
CPT Codes 82108
Test Schedule Mon-Fri
Turnaround Time 2-5 days
Method ICP/MS
Test Includes Time, hr; Volume, mL; Creatinine, Urine, mg/dL; Creatinine, Urine, mg/d; Aluminum, Urine, ug/L; Aluminum, Urine, ug/d; Aluminum, Urine ug/gCreat.
Reference Ranges
Collection Period                hr
Volume                           mL
Creatinine, Urine                mg/dL
Creatinine, Urine                mg/d
 M 0-2 yrs       Not established 
   3-8 yrs       140-700
   9-12 yrs      300-1300
   13-17 yrs     500-2300
   18-50 yrs     1000-2500    
   51-80 yrs     800-2100
   81+ yrs       600-2000
 F 0-2 yrs       Not established
   3-8 yrs       140-700
   9-12 yrs      300-1300
   13-17 yrs     400-1600
   18-50 yrs     700-1600
   51-80 yrs     500-1400
   81+ yrs       400-1300
Aluminum, Urine     0-7           ug/L
Aluminum, Urine     0-10          ug/d
Aluminum, Urine     No reference  ug/gCr
                    range established.
                    Urine aluminum values
                    do not correlate well
                    with exposure. Elevated
                    levels should be 
                    confirmed with a second
                    specimen due to a high
                    susceptibility of the
                    specimen to collection-
                    related environmental
                    contamination.
search  |  back

:: Interface Codes ::

typeorder codetest descriptionresult coderesult descriptionunitsdecimal placesloinc code
o84999.Z21Aluminum, Urine Quant
r84999.Z21Aluminum, Urine Quant82108.Z1Aluminum, Urine - ug/Lug/L05577-2
r84999.Z21Aluminum, Urine Quant82108.Z2Aluminum, Urine - ug/dayug/d026707-0
r84999.Z21Aluminum, Urine Quant82108.Z3Aluminum, Urine - ug/g CRTug/gCR129937-0
r84999.Z21Aluminum, Urine Quant82108.Z4Timehr 13362-9
r84999.Z21Aluminum, Urine Quant82108.Z5VolumemL 3167-4
r84999.Z21Aluminum, Urine Quant82570.Z2Creatinine, Urine - mg/daymg/d02162-6
r84999.Z21Aluminum, Urine Quant82570.Z3Creatinine,Urine-mg/dLmg/dL02161-8


Questions/Comments